TTS unlimited /Hardness TestersMeasuring Tools / InstrumentsCutting ToolsMicroscopes / Optical EquipmentsPrecision Tool / Machine Tool Access
TTS TOP ABOUT TTS MAIL FORM

represents Japanese best quality manufactures in the various Industrial fields

product category /Hardness TestersMeasuring Tools / InstrumentsCutting ToolsMicroscopes / Optical EquipmentsPrecision Tool / Machine Tool Access

TTS unlimited,inc.

1-3-2500 Umeda 1-Chome
Kita-Ku, Osaka 530-0001
Japan

Phone : 81-6-6347-0685
Fax : 81-6-6347-7555

If you have any requirement or Information, Please feel free to contact us !!
 

 
TOP > Measuring Tool / Instrument > Clamp Earth Tester

Clamp Earth Tester

 
Clamp Earth Tester

‘Model : MET-1

Model : MET-1

ECompletely different method from theordinary

  Earth Testers.
EJust Clamping two CTs to the earthing

   conductorand no need to using auxillary eath

   rod !!

Model : MET-1

This Clamp Earth Tester Model : MET-1 measure the earth resistance by using two clamp CTs
without disconnecting the earthing conductor and without using auxillary ground rod can
measure only the objective earth resistance without any influence from other conductors.


Appplications for Measuring of Earth Resistance


1 Outer case & iron stand of extra high tension

   cable and high voltage appliance.
2  Lighting arrester.
3 Transformer at output end for the extra high

   voltage measuring appliance.
4  Confirming the grounding of the conductors 

    for equipotentia bonding.
5  Stic electricity preventsion equipment &

    appliance.
6  Mulitiple earthSpecifications

Model : MET-1

Specifications

Measuring function

Earth Resistance, AC Current (Line & Leakage)

Measuring method

Dual intergration mode, Clamping two CTs

Display

LCD, 16 letters / characters x 2 lines with contrast adjustor

Safety standard

Meets the requirements for double insulation to IEC 1010-2 installation category II. 600V phase to earth

Sampling

Approx. 2 times / second for AC current

Measuring Time

Approx. 30 second for earth resistance

Over range indication

"OVER" on LCD readout both for AC current & earth resistance

Low battery indication

"B" mark on LCD readout

Auto power off

The meteris set to power off mode, approx. 5 minutes after the power swich on.

Data hold function

"DH" mark on LCD readout

Accuracy

23Ž}5Ž, 80% RH max.

Eath Resistance

Range Resolution Accuracy
200ƒΆ 0.1ƒΆ 0 ` 10ƒΆ@@@@}0.2ƒΆ
10 ` 50ƒΆ@@ @}1.0ƒΆ
50 ` 200ƒΆ @@}5.0ƒΆ

AC Current (Max. applicable current : F10A rms)

Range

Resolution

Accuracy

200mA

0.1mA

2% rdg } 8 dgt

2000mA

1mA

10A

0.01A


CT for decection  340mm
CT for superposition 340mm, auto sweep 4KHz ` 400KHz

Superposing level : approx. 160mVp 

Storage temperature -10Ž`60Ž, ƒ80% RH without condensation
Operating temperature 0Ž`40Ž, ƒ80% RH without condensation
Circuit voltage less than 500V
Withstanding Voltage AC 3700V, 1minute between operation handle

and CT core 
AC 2300V, 1minute between supply cource

and body case of the instrument

Power Supply AC100V `240V (50Hz/60Hz) with 

adaptorInternal Ni-Cd battery (1.2 x 5) 

Battery life 450 times measurement under full charged

condition ( according to the time of chargeing

and discharging).

Size & Weight
CT for Detection 90.5(W) x 165(H) x 38(D)mm, approx. 460g
CT for superposition 90.5(W) x 165(H) x 38(D)mm, approx. 440g
Instrument body 190(W) x 140(H) x 42(D)mm, approx. 800g
Standard accessories Detection Clamp CT EEEE@1
Superpotion Clamp CTEEE@1
AC AdaptorEEEEEEEEEEE@1
Carrying caseEEEEEEEEE@1
Instrument bodyEEEEEEE@1
Subsidary lead wireEEEEE@1
@
@